This is a cached page for the URL (http://www.med.umich.edu/tamc/injDNA.html). To see the most recent version of this page, please click here.
Protocol Online is not affiliated with the authors of this page nor responsible for its content.
About Cache
TGB  


 
 

Microinjection DNA Purification

We have found the NucleoSpinTM Extract Kit (available from Clontech, Catalog number K3051-1) is a simple and fast way to obtain microinjection quality DNA. This is not to exclude other methods of DNA purification but to say that we find this is a convenient method that is less onerous than CsCl gradients.

1. Perform restriction digest to liberate transgene from plasmid vector sequences. Final yield should be 10 - 20 micrograms of transgene insert.

2. Separate restriction digest products on agarose gel using either TBE or TAE.
Use either low- or standard- melting temperature agarose.

3. Place gel on transilluminator. Cut out band(s) of interest. Use a clean razor blade or scalpel.
Remove as much excess agarose as possible. Minimize DNA exposure to UV light to prevent photochemical damage (less than 1 minute).

4. Transfer agarose slice(s) to a preweighed tube. Reweigh tube to determine weight of agarose in tube.

5. For each 100 mg of gel, add 300 microliters buffer NT1. If agarose concentration is greater than 1%, add proportionately more buffer. For example, if a 2% agarose gel is used, add 600 microliters buffer NT1 for each 100 mg of gel.

6. Dissolve at 50 degrees Centigrade for 10 minutes, vigorously vortexing every 2 to 3 minutes.

7. Place a NucleoSpinTM cartridge in a 2 ml micro tube and load 750 microliters dissolved gel slice onto the cartridge. Spin at maximum speed for 60 seconds in a microcentrifuge. Discard the flowthrough. The cartridge has a capacity of 2 micrograms DNA, so you can run several 750 microliters loads of dissolved gel slice through a single cartridge.

8. Add 750 microliters of buffer NT3 to the cartridge and spin at maximum speed for 60 seconds in a microcentrifuge. Discard the flowthrough.

9. Replace tube with a fresh microtube. Spin the empty cartridge at maximum speed for
60 seconds in a microcentrifuge to completely remove buffer NT3.

10. Elute the DNA from the cartridge: Replace tube with a fresh microtube. Add 50 microliters of preheated (60 degrees Centigrade) elution buffer to cartridge. Spin at maximum speed for 60 seconds in a microcentrifuge.
Elution buffer: 10 mM Tris-HCl, pH 8.5, 0.02 micron filtered. Check the pH of the elution before just before you use it, best yields are obtained at a pH of 8.5 or greater. The 0.02 micron Anotop syringe filters are available from Whatman.

11. If desired, repeat step 10 to increase yield. We obtain 90% of the DNA in the first elution.

12. Quantitate DNA solution.

13. Verify size and intact condition of DNA on minigel.

14. Store eluted DNA at -20 degrees Centigrade.

Top Home

Transgenic Outline | Gene Targeting Outline | List of Services | Service Description
Genotyping Mice |Mouse Breeding Suggestions | Links|Home


comments to: tsaunder@umich.edu