Recommended working medium, trypsin volume and cell inoculation density

Author: Long-Cheng Li

Source:
Abstract: Useful data for cell subculture with different culture vessels.
Date Added: 2002-05-14
Date Modified: 2004-04-27

 

Recommended working medium, trypsin volume

and cell inoculation density

(7/9/99)

 

Type of Vessels

Culture Area (cm2)

Volume (ml)

Working Medium (ml)

Inoculation Density

Volume of Trypsin (ml)

Nunclon Flask

24

50

7

4.8x105

0.5-0.8

Corning Flask

25

70

7

5x105

0.5-0.8

Falcon Flask

75

250

25

1.5x106

1.0

Nunclon Flask

83

260

30

1.6x106

1.2

Nunclon Flask

175

800

68

3.5x106

2.0

Falcon Dish 35x10mm

9.6

 

2.5

1.6x105

0.2-0.3

Falcon Dish 65x15mm

21

 

6.0

4.2x105

0.5-0.6

Falcon Dish 100x20mm

58

 

16.0

1.1x106

1.0

96 well Plate

0.32

 

0.2

6x103

0.01-0.02

24 well Plate

1.88

 

1.5

3.7x104

0.08-0.1

12 well Plate

3.83

 

2.0

7.6x104

0.1-0.2

6 well Plate

9.4

 

3.0

1.8x105

0.2-0.3

 